DS10 A and C - ADVANCED FILTER FAILURE DETECTOR
                   FOR DUST ARRESTMENT PLANT
 
 
 
        
 
 
                 
                
 
*  Dual Alarms (early warning and failure)
*  Alarm status and system check LED
*  Uniqute patented TriboAce Technology 
   (increased reliability over triboelectric
   systems)
*  Digital averaging avoids false alarms from
   baghouse cleaning pulses
*  Combined sensor and control unit 
   (c version)
   or seprate sensor and control unit
   (a version)
 
 
 
                                      (please click on a link below to go directly to that point on this page)
 
 
                                                          System Description
 
The DustSense 10 series of advanced continuous particulate monitors are based on PCME's unique patented TriboACE technology, giving added reliability and sensitivity over standard Triboelectric systems.  
 
The DustSense 10's alarm levels can be set as a factor or percentage of the background level of particulate.  The user has the ability to set the alarms to instantaneous or average levels above the background or normal level of emissions to indicate early warning of filter failure or gross failure detection.  Alarm delay and data averaging are user selectable.
 
Commissioning is simple and requires no tools or specialized equipment.  The DustSense 10 series complies with the U.K.'s EPA for filter failure detection for Part A and Part B processes and European regulations for filter failure monitoring.
 
Two versions are available - an "a" version, which comprises a separate sensor and control unit connected by a calbe, and a "c" version, which is a combined sensor and control unit that is mounted in the stack or duct.  Two separate alarm relay outputs are available within each mode.
 
  
                                              User Controls and Functions
 
Reference Period
User defined from 1 minute to 60 minutes
Alarm Level 1
Adjustable 1 - 10,000 units
Alarm Level 2
50% of alarm level 1 (fixed setting)
Data Smoothing
1 minute data averaging
Alarm Delay
up to 1 minute or 2 minutes
Relay Outputs
2 separate relays, voltage free contacts.  Rated 2 Amp @ 250 Vac
 
 
 
                                                        Specifications
 
 
                           DS10A 
             DS10C
Control Unit
Sensor
Combined Unit
Enclosure Rating
IP 65
IP 65
IP 65
Enclosure Size (mm)
75l x 80h x 55d
75l x 81h x 57d
75l x 81h x 57d
Enclosure Weight
700 gms (1 1/4 lbs)
500 gms (1 lb)
500 gms (1 lb)
Power Supply
115/230Vac 50/60 Hz
N/a
24v dc@40mA (option)
Relay Contacts
2 of 2 Amps @ 250 Vac
N/a
2 of 2 Amps @ 250 Vac
Ambient Temperature
-20C to +50C (-65F to +125F)
-20C to +50C (-65F to +125F)
-20C to +50C (-65F to +125F)
Display
Tri-state LED (alarm 1, 2 and status)
N/a
Tri-state LED (alarm 1, 2 and status)
Cable Lengths
N/a
10 to 300 m (10 m std) (30-100 ft)
N/a
Cable to Control Unit
N/a
8 core screened
N/a
Stack/Duct Connection
N/a
1/2 inch BSP (female)
Sensor Lengths
N/a
100, 250, 500, 750, 1000 mm (4, 10, 20, 30, 40 inches nominal)
Sensor Material
N/a
316 stainless steel, PTFE insulator
Stack Gas Temperature
N/a
Standard:  -20C to +125 C (-65F to +250F)
Optional:  up to 250C (500F)
For higher temperatures, please consult a representative or call 919-790-9090
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
   

 
PCME-US is a division of B3 Systems, Inc.
B3 Systems, Inc. is an independent distributor of PCME, Ltd. products.
 
 
7711 Welborn Street
Suite 106
Raleigh, NC  27615
 
Phone 919-790-9090
Fax 919-790-0550
 

© 2004 B3 Systems, Inc.