DS10 A and C - ADVANCED FILTER FAILURE DETECTOR
FOR DUST ARRESTMENT PLANT
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
* Dual Alarms (early warning and failure)
* Alarm status and system check LED
* Uniqute patented TriboAce Technology
(increased reliability over triboelectric
systems)
* Digital averaging avoids false alarms from
baghouse cleaning pulses
* Combined sensor and control unit
(c version)
or seprate sensor and control unit
(a version)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
(please click on a link below to go directly to that point on this page)
System Description
The
DustSense 10 series of advanced continuous particulate monitors are
based on PCME's unique patented TriboACE technology, giving added
reliability and sensitivity over standard Triboelectric
systems.
The
DustSense 10's alarm levels can be set as a factor or percentage of the
background level of particulate. The user has the ability to set
the alarms to instantaneous or average levels above the background or
normal level of emissions to indicate early warning of filter failure
or gross failure detection. Alarm delay and data averaging are
user selectable.
Commissioning
is simple and requires no tools or specialized equipment. The
DustSense 10 series complies with the U.K.'s EPA for filter failure
detection for Part A and Part B processes and European regulations for
filter failure monitoring.
Two
versions are available - an "a" version, which comprises a separate
sensor and control unit connected by a calbe, and a "c" version, which
is a combined sensor and control unit that is mounted in the stack or
duct. Two separate alarm relay outputs are available within each
mode.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

© 2004 B3 Systems, Inc.