DS30A, C and D - ADVANCED PARTICULATE MONITOR
FOR DUST ARRESTMENT PLANT
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
* Scaleable 4 - 20mA output
* Dual Alarms (early warning and failure)
* Digital disply reading on percentage dust level
(DS30A version only)
* Digital averaging minimises false alarms from
pulsing baghouses
* Unique patented TriboACE technology
(increased reliability over Triboelectric systems)
* Combined sensor and control unit (C version) or
separate sensor and control unit (A version)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
(please click on a link below to go directly to that area on this page)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
System Description
The DustSense 30 series is based on PCME's unique patented
TriboACE technology giving more reliable operation than Triboelectric
dust monitors. Once installed in the emission stack or exhaust
duct, the average background level of particulate can be defined.
The alarm levels can then be set to a percentage or factor above this
background reference level. A digital display (#) displays the
percentage of dust in relation to the alarm level, having a span of
0-200% of the chosen alarm level setting. The 4-20mA output is
scaled 0-200% of alarm level 1, allowing the operator to determine how
the dust level is compared to a pre-determined limit or warning level.
The two alarm levels can be used to set both warning and
emission limit levels to assist operators in potential failures from
their arrestment plant. Alarm delay and data averaging are user
selectable.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

© 2004 B3 Systems, Inc.