DS30A, C and D - ADVANCED PARTICULATE MONITOR
                                FOR DUST ARRESTMENT PLANT
 
 
 
 
 
 
 
          
 
 
*  Scaleable 4 - 20mA output
*  Dual Alarms (early warning and failure)
*  Digital disply reading on percentage dust level
   (DS30A version only)
*  Digital averaging minimises false alarms from
   pulsing baghouses
*  Unique patented TriboACE technology
   (increased reliability over Triboelectric systems)
*  Combined sensor and control unit (C version) or
    separate sensor and control unit (A version)
                                        (please click on a link below to go directly to that area on this page)
 
 
                                                 System Description
 
The DustSense 30 series is based on PCME's unique patented TriboACE technology giving more reliable operation than Triboelectric dust monitors.  Once installed in the emission stack or exhaust duct, the average background level of particulate can be defined.  The alarm levels can then be set to a percentage or factor above this background reference level.  A digital display (#) displays the percentage of dust in relation to the alarm level, having a span of 0-200% of the chosen alarm level setting.  The 4-20mA output is scaled 0-200% of alarm level 1, allowing the operator to determine how the dust level is compared to a pre-determined limit or warning level.
 
The two alarm levels can be used to set both warning and emission limit levels to assist operators in potential failures from their arrestment plant.  Alarm delay and data averaging are user selectable.  
 
 
  
                                             User Controls and Functions
 
Reference Period
User defined from 1 minute to 60 minutes
Alarm Level 1
Adjustable 1 - 10,000 units
Alarm Level 2
50% of alarm level 1 (fixed setting)
Data Smoothing
1 minute data averaging
Alarm Delay
up to 1 minute or 2 minutes
Relay Outputs
2 separate relays, voltage free contacts.  Rated 2 Amp @ 250 Vac
 
 
 
                                                        Specifications
 
 
                           DS10A 
             DS10C
Control Unit
Sensor
Combined Unit
Enclosure Rating
IP 65
IP 65
IP 65
Enclosure Size (mm)
75l x 80h x 55d
75l x 81h x 57d
75l x 81h x 57d
Enclosure Weight
700 gms (1 1/4 lbs)
500 gms (1 lb)
500 gms (1 lb)
Power Supply
115/230Vac 50/60 Hz
N/a
24v dc@40mA (option)
Relay Contacts
2 of 2 Amps @ 250 Vac
N/a
2 of 2 Amps @ 250 Vac
Ambient Temperature
-20C to +50C (-65F to +125F)
-20C to +50C (-65F to +125F)
-20C to +50C (-65F to +125F)
Display
Tri-state LED (alarm 1, 2 and status)
N/a
Tri-state LED (alarm 1, 2 and status)
Cable Lengths
N/a
10 to 300 m (10 m std) (30-100 ft)
N/a
Cable to Control Unit
N/a
8 core screened
N/a
Stack/Duct Connection
N/a
1/2 inch BSP (female)
Sensor Lengths
N/a
100, 250, 500, 750, 1000 mm (4, 10, 20, 30, 40 inches nominal)
Sensor Material
N/a
316 stainless steel, PTFE insulator
Stack Gas Temperature
N/a
Standard:  -20C to +125 C (-65F to +250F)
Optional:  up to 250C (500F)
For higher temperatures, please consult a representative or call 919-790-9090
   


 
PCME-US is a division of B3 Systems, Inc.
B3 Systems, Inc. is an independent distributor of PCME, Ltd. products.
 
 
7711 Welborn Street
Suite 106
Raleigh, NC  27615
 
Phone 919-790-9090
Fax 919-790-0550
 

© 2004 B3 Systems, Inc.