The more you learn about PCME sensor technology, the more you will be convinced that they offer unique capabilities.
MACT stands
for maximum achievable control technology. If your industry has
been identified by EPA as a major source of metals or other particulate
emissions and you operate a baghouse for particulate control, you will
likely have a MACT requirement to install a fabric filter leak
detection system. Although the language differs slightly from
industry to industry, the effect is the same. EPA requires
that you follow certain procedures to ensure that data from the leak
detection system is reliable (see the sample language below).
![]() |
||
|
The procedures for leak detection systems are spelled out in
an EPA Guidance Document. You may download the document using the
icon below:
![]() |
||
|
Baghouse leak detectors are installed as indicators of
fabric filter performance. The results from the leak detectors
are NOT meant to be correlated with particulate emission test
results. The results from the sensor are recorded during a
representative period of well-controlled emissions and alarm level is
set based on those results.
The guidance document provides procedures for the initial
and periodic setup of the alarm point. It also contains required
on-going quality assurance procedures to make sure that the monitoring
system is functioning properly (see below).
|
||
|
The EPA Guidance requires that you conduct the following quality assurance checks:
* Monthly zero and span electronic drift checks,
* Periodic probe inspection and cleaning for dust-build-up, and
* Yearly sensor alarm setup
The Guidance Document requirement for monthly checks is shown below:
![]() |
||
|
The procedures for conducting the electronic drift checks are highlighted below:
![]() |
||
|
For some probe systems, these procedures require significant
labor by a technician as well as specialized equipment to generate the
required signals (pico amps). The patented PCME DT990 probe
conducts these electronic checks automatically and the results are
displayed on the operator interface. In the event that a
calibration check fails, an alarm is generated and the alarm log in the
user interface is updated.
The requirement for periodic sensor cleaning can also be a
labor-intensive activity. The highlighted section below describes
the requirement in the Guidance Document:
![]() |
||
|
This requires you to periodically remove the probe and clean
it, although it can be difficult to determine how often this cleaning
must occur. Excessive dust build-up can either cause alarm
conditions to be suppressed or it can also cause false alarms.
The PCME DT990 probe has a patented electronic procedure
called a contamination check. By sensing the difference between
the current from the measuring probe and a check probe, the sensor
generates a “percent contamination” result that actually
reflects how dust build-up is affecting the measurement. The
contamination result is available at the operator interface at all
times. When the contamination result exceeds 25% an alarm is
generated and logged. This alarm is the operator’s cue to
initiate the cleaning procedure.
MACT standards also require you to set the alarm point of
the leak detection system at least once per year. The alarm point
is based on the typical response of the detector during normal
operation of the baghouse. The alarm point also needs to be
adjusted whenever the characteristics of the particulate change.
If the size, composition, or charge of the particulate changes; the
response of the leak detector will change as well. B3 Systems can
conduct the initial installation and setup of the leak detector system
(see Service Plan). We also offer a yearly service contract that
includes the yearly setup. Because of the digital communication
properties of the PCME network, setup and diagnostics can be conducted
remotely using a modem or Ethernet connection.
|
||
|
Our team of MACT compliance experts are ready to answer your
questions about how to implement the regulations at your
facility. We can also help with finding the right sensor for your
particular application.
|
||
|